Vytvorené: 25. 12. 2022 Tlačiť

Pneumatic
Compressor
Variable compressor
Air service unit
Compressed air supply
Air service unit, simplified representation
Air pressure reservoir
Air pressure reservoir
Air filter
Manual drain filter
Automatic drain filter
Manual drain
Automatic drain
Lubricator
Cooler
Air Dryer
Distance rule
Single acting cylinder
Cylinder, Single-acting, Return Spring in Piston Chamber
Double acting cylinder
Cylinder without piston rod
Cylinder with two piston rods
Multiple Position Cylinder, Double-acting
Air motor
Semi-rotary actuator
Vacuum suction nozzle
Sucker
Linear Drive, Pneumatic, with Shape-fiiting Adaptor
Linear Drive, Pneumatic, with Shape-fitting Adaptor
Linear Drive with solenoid coupling
Cylinder, Double–acting, with Two Piston Rods and Single Trestle
Cylinder, Double–acting, with Two In and Out Piston Rods and Double Trestle
Double acting cylinder
Single acting cylinder
Cylinder, Double-acting, with in and out Piston Rod
Cylinder, Single-acting, Return Spring in Piston Chamber
Valves
2/h Way Valve
3/h Way Valve
4/h Way Valve
5/h Way Valve
6/h-way directional valve
8/h-way directional valve
Frequently Used Way Valves
3/2-way valve with pushbutton
3/2-way valve with pushbutton
3/2-way valve, manually operated
5/2 valve with selection switch
3/2-way roller lever valve
3/2-way idle return roller lever valve
Pneumatic proximity switch, solenoid operated
Pressurizing valve
3/2-way roller lever valve
3/2-way valve, pneumatically operated
3/2-way valve, pneumatically operated
5/2-way valve, pneumatically operated
5/3-way valve, pneumatically operated
Low pressure amplifier unit 2 compartments
5/2-way impulse valve, pneumatically operated
Valve Solenoid
3/2-way solenoid valve
3/2-way solenoid valve
5/2-way solenoid valve
5/2-way solenoid impulse valve
5/3-way solenoid valve
5/2-way solenoid valve
5/2-way solenoid valve
Pneumatic timer, normally closed
Pneumatic timer, normally open
Nozzle
Throttle valve
Orifice
Variable orifice
One-way flow control valve
Shuttle valve
Two pressure valve
Quick exhaust valve
Check valve
Spring loaded check valve
Check valve with pilot control
Spring loaded pilot-operated check valve
Pilot to close check valve
Pilot to close spring loaded spring loaded valve
Pneumatic counter
Pressure reducing valve
Variable pressure reducing valve
Pressure reducing valve
Variable pressure reducing valve
Pressure control valve with manometer
Closing pressure compensator
Variable closing pressure compensator
Opening pressure compensator
Variable opening pressure compensator
Proportional 5/3-way directional valve
Proportional valve solenoid, position controlled
Stepper Module, type TAA
Stepper Module, type TAB
Two-hand control block
Quickstepper
Pressure sequence valve
Time delay valve, normally closed
Time delay valve, normally open
Adjustable vacuum actuator valve
Manometer
Differential pressure gauge
Pressure indicator
Flow meter
Flow meter
Analog flow meter
Pressure sensor
Differential pressure switch
Ring sensor
Analog pressure sensor
Electrical Controls
Solenoid
DC Motor
Electrical connection 0V
Electrical connection 24V
Function generator
Setpoint value card
Pressure sensor
Analog pressure sensor
Analog flow meter
Pneumatic to electric converter
Displacement encoder
Voltmeter
Ampere meter
Indicator light
Buzzer
Relay
Relay with switch-on delay
Relay wtih switch-off delay
Relay counter
Valve solenoid
Proportional valve solenoid, position controlled
Starting current limiter
Switches
Pushbutton (make)
Detent Switch (make)
Detent Switch (break)
Pushbutton (changeover)
Pushbutton (break)
Detent Switch (changeover)
Break switch
Make switch
Changeover switch
Capacitive proximity switch
Magnetic proximity switch
Inductive proximity switch
Optical proximity switch
Comparator
PID Controller
Status controller
Electrical connection 0V
Electrical connection 24V
Pushbutton (make, Ladder)
Pushbutton (break, Ladder)
Pushbutton (changeover, Ladder)
Make switch (Ladder)
Brake switch (Ladder)
Valve solenoid
Relay (Ladder)
Relay with switch-off delay (Ladder)
Relay with switch-on delay (Ladder)
Indicator light
Logic module
Logic module
Lo level
Hi level
Input
Output
Buffer
AND
OR
NOT
AND with edge triggering
NAND
NAND with edge triggering
NOR
XOR
Latching relay
Symetric clock generator
Asynchronous pulse generator
Pulse relay
On delay
Retentive on delay
Off delay
On/off delay
Wiping Relay – Pulse Output
Edge-triggered wiping relay
Up and down counter
Frequency trigger
Timer switch
Multi-pin plug distributor
Universal–I/0
FluidSIM Input Port
FluidSIM Output Port
Step
Transition
Action
Synchronization
Partial GRAFCET
GRAFCET I/0
State Diagram
Functional diagram
Terminal assignment diagram
Parts List
Text 
Bitmat
Square
Circle
Elipse
Rectangle
 
Hodnotenie užitočnosti článku:


    Umela inteligencia Novy narodopis Teoria poezie 3D-tlac Arduino Nove rekordy Prudove chranice Robotika Priemysel 4.0 Dejiny Slovenska do roku 1945 ang_znacky_fluidsim LOGOSoftComfort Novinky Historia elektromobilov Free e-kurzy Elektrina pre ZŠ Druhá svetová vojna Cvičebnice O troch pilieroch EP je spat Prehlad Fyzika Prehlad Informatika Ako sa učiť a ako učiť Dejiny sveta

     

    · Simulácie z fyziky 
    · O Slovensku po slovensky 
    · Slovenské kroje
    · Kurz národopisu
    · Diela maliarov
    · Kontrolné otázky, Domáce úlohy, E-testy - Priemysel
    · Odborné obrázkové slovníky
    · Poradňa žiadaného učiteľa
    · Rýchlokurz Angličtiny
    . Rozprávky (v mp3)
    · PREHĽADY (PRIBUDLO, ČO JE NOVÉ?)
    Seriály:
    · História sveta (1÷6)
    · História Slovenska (1÷5)
    · História módy (1÷5).

                                       
    Členstvo na portáli
    Mám účet a chcem sa prihlásiť Prihlásiť sa
    Nemám účet, ale chcel by som ho získať Registrovať sa
    Poznámka pre autora

    Ak ste na stránke našli chybu, dajte nám vedieť


    Copyright © 2013-2024 Wesline, s.r.o. Všetky práva vyhradené. Mapa stránky ako tabuľka | Kurzy | Prehľady